You are required to read and agree to the below before accessing a full-text version of an article in the IDE article repository.

The full-text document you are about to access is subject to national and international copyright laws. In most cases (but not necessarily all) the consequence is that personal use is allowed given that the copyright owner is duly acknowledged and respected. All other use (typically) require an explicit permission (often in writing) by the copyright owner.

For the reports in this repository we specifically note that

  • the use of articles under IEEE copyright is governed by the IEEE copyright policy (available at http://www.ieee.org/web/publications/rights/copyrightpolicy.html)
  • the use of articles under ACM copyright is governed by the ACM copyright policy (available at http://www.acm.org/pubs/copyright_policy/)
    ss
  • technical reports and other articles issued by Mälardalen University is free for personal use. For other use, the explicit consent of the authors is required
  • in other cases, please contact the copyright owner for detailed information

By accepting I agree to acknowledge and respect the rights of the copyright owner of the document I am about to access.

If you are in doubt, feel free to contact webmaster@ide.mdh.se

Achieving security through network traffic monitoring for industrial applications

Type:

Seminar

Start time:

2016-02-22 13:15

End time:

2016-02-22 14:30

Location:

MDH, room U2-097

Contact person:



Description

Today, industrial networks are often used for safety-critical applications with real-time requirements. The architecture of such applications usually has a time-triggered nature that has message scheduling as a core property. Real-time scheduling can be applied only in networks where nodes share the same notion of time, i.e. they are synchronized. Therefore, clock synchronization is one of the fundamental assets of industrial networks with real-time requirements. Usually, standards for clock synchronization, i.e. IEEE 1588, do not provide the required level of security. This raises the question about clock synchronization protection. 
We show that it is possible to break clock synchronization established according to IEEE 1588 by conducting a man-in-the-middle (MIM) attack combined with a following up delay attack. A MIM attack can be accomplished through e.g., Address Resolution Protocol (ARP) poisoning. 
Network monitoring can be considered as a technique to detect anomalies introduced by an adversary performing attacks targeting clock synchronization. The monitoring capabilities can be added to the network using a Configuration Agent, which, based on data obtained from the network, is capable of detecting certain types of attacks. 
We present an analysis of the consequences of the introduced delays. It shows that the attack can, indeed, break clock synchronization. A set of mitigation techniques is presented and evaluated for its applicability in the considered networks.

This presentation is sponsored by the EU Marie Curie project RetNet.