You are required to read and agree to the below before accessing a full-text version of an article in the IDE article repository.

The full-text document you are about to access is subject to national and international copyright laws. In most cases (but not necessarily all) the consequence is that personal use is allowed given that the copyright owner is duly acknowledged and respected. All other use (typically) require an explicit permission (often in writing) by the copyright owner.

For the reports in this repository we specifically note that

  • the use of articles under IEEE copyright is governed by the IEEE copyright policy (available at http://www.ieee.org/web/publications/rights/copyrightpolicy.html)
  • the use of articles under ACM copyright is governed by the ACM copyright policy (available at http://www.acm.org/pubs/copyright_policy/)
  • technical reports and other articles issued by M‰lardalen University is free for personal use. For other use, the explicit consent of the authors is required
  • in other cases, please contact the copyright owner for detailed information

By accepting I agree to acknowledge and respect the rights of the copyright owner of the document I am about to access.

If you are in doubt, feel free to contact webmaster@ide.mdh.se

Improved breath alcohol analysis in patients with depressed consciousness

Research group:


Publication Type:

Journal article

Venue:

Medical & Biologicakl Engineering & Computing

Publisher:

Springer

DOI:

DOI: 10.1007/s11517-010-0655-5


Abstract

Many patients in pre-hospital and emergency care are under the influence of alcohol. In addition, some of the more common pathological conditions can introduce a behaviour that can be mistaken to be related to alcohol inebriation. Fast quantitative determination of the breath alcohol concentration (BrAC) in emergency patients facilitates triage and medical assessment, but shallow expirations performed by non-cooperative patients reduce the measurement reliability. The aim of this study was to evaluate if breath alcohol analysis in non-cooperative patients can be improved with use of simultaneous measurement of the expired carbon dioxide (CO2). With prototypes of a handheld breath alcohol analyser based on infrared transmission spectroscopy the alcohol and CO2 concentration in expired breath from 37 cooperative and non-cooperative patients were measured. The results show that enhanced breath sampling with use of a pump and estimation of the end expiratory BrAC with use of the ratio between the measured partial pressure of CO2 ($$ P_{{{ ext{CO}}_{2} }} $$) and a reference value of the alveolar $$ P_{{{ ext{CO}}_{2} }} $$, provided adequate correlation with the blood alcohol concentration (BAC). This pre-clinical study has shown that breath alcohol analysis in shallow expirations from non-cooperative patients can be improved with use of CO2 as a tracer gas.

Bibtex

@article{Kaisdotter Andersson (Jonsson)1948,
author = {Annika Kaisdotter Andersson (Jonsson) and Bertil H{\"o}k and Mikael Ekstr{\"o}m},
title = {Improved breath alcohol analysis in patients with depressed consciousness},
volume = {48},
number = {11},
pages = {1099--1105},
month = {October},
year = {2010},
journal = {Medical {\&} Biologicakl Engineering {\&} Computing },
publisher = {Springer},
url = {http://www.es.mdu.se/publications/1948-}
}